- Baxter Flo-Gard 6200 -

Baxter Flo-Gard 6200

Baxter Flo-Gard 6200

The Baxter Flo-Gard® 6200 volumetric infusion pump is the industry standard in set infusion pump technology. It can deliver a wide variety of fluids over a broad range of infusion rates.

Features
  • Easy to load, spill-resistant pumping mechanism
  • Occlusion sensors that detect both upstream and downstream restrictions
  • Ultrasonic air detector that senses bubbles approximately 50 microliters or larger without nuisance alarms
  • Safety clamp mechanism that prevents accidental free flow
  • Locking control panel that prevents tampering
  • Independent secondary medication program that automatically switches over to primary program upon completion
  • Uses standard Baxter solution administration sets
  • Automatic self-test routine that checks for proper function before use
  • Five hour memory which retains infusion data after power-off
  • Easily replaceable fuse, battery, and power cord

phone Call for price: (855) 477-8866

Download the operator's Manual

Description

Baxter Flo-Gard 6200

So here you will be able to find the specifications of the Baxter Flo-Gard 6200 Infusion Pump Repair and baxter flo gard 6200 manual. Here are the dimensions, weight, pump type, flow rate range and  etc. Download baxter flo gard 6200 service manual

  • Pump Type: Linear peristaltic volumetric infusion pump
  • Dimensions: 9.5 W x 11 H x 6 D in.
  • Weight: 14 lbs
  • Flow Rate Range: (Primary program): 1-999 mL/hr in 1 mL increments for both primary and secondary
  • VTBI Range: 1-9999 mL for both primary and secondary
  • KVO Rate: 5 mL/hr or programmed rate, whichever is less
  • Output Pressure: Initial distal occlusion alarm pressure is approximately 5-7 psi
  • Air-in-Line Detection: Air bubbles approximately 50 microliters or larger
  • Nurse Call: Optional – an installation kit is required
  • Battery Life: 5 hours on fully charged batteries at a rate of 125 mL/hr
  • Battery Recharge: 16 hours to recharge 80% of capacity
  • AC Power Requirements: 110/120V, 60 Hz
  • Power Cord: 8 ft, Hospital Grade Plug
  • Fuse: 0.5 A, 250 V, SB, 6.35 mm x 31.8 mm
  • Leakage Current: Less than 50 microamps (using UL specified test methods)
  • Baxter Flo-Gard 6200

    Download baxter flo gard 6200 service manual

    Pump Type: Linear peristaltic volumetric infusion pump

    Dimensions: 9.5 W x 11 H x 6 D in.

    Weight: 14 lbs

    Flow Rate Range: (Primary program): 1-999 mL/hr in 1 mL increments for both primary and secondary

    VTBI Range: 1-9999 mL for both primary and secondary

    KVO Rate: 5 mL/hr or programmed rate, whichever is less

    Output Pressure: Initial distal occlusion alarm pressure is approximately 5-7 psi

    Air-in-Line Detection: Air bubbles approximately 50 microliters or larger

    Nurse Call: Optional – an installation kit is required

    Battery Life: 5 hours on fully charged batteries at a rate of 125 mL/hr

    Battery Recharge: 16 hours to recharge 80% of capacity

    AC Power Requirements: 110/120V, 60 Hz

    Power Cord: 8 ft, Hospital Grade Plug

    Fuse: 0.5 A, 250 V, SB, 6.35 mm x 31.8 mm

    Leakage Current: Less than 50 microamps (using UL specified test methods)