- Abbott Plum XL -

Abbott Plum XL

Abbott Plum XL

The Plum XL is a dual-line volumetric infusion system designed to meet the growing demand for hospital-wide standardization. With its primary line, secondary line, and piggyback fluid delivery capability, the Plum XL is suited for a wide range of general floor, critical care, and home care applications. Compatibility with LifeCare® 5000 PlumSet® administration sets and accessories makes the Plum XL a convenient and cost-effective system.

Features
  • Large LCD display
  • Volume to be Infused (VTBI) setting
  • Safeguards to protect against over-delivery:
    • Motor speed is continuously monitored
    • Firmware senses malfunctions that could result in gravity flow
  • Volume infused accumulation displays for primary and secondary solutions
  • Non-pulsatile volumetric accuracy
  • Microprocessor control
  • Titration
  • Self-test
  • Simple setup (one hand cassette loading)
  • Automatic memory retention of all previous therapy settings and fluid delivery data, until cleared by user
  • Two-level adjustable alarm volume
  • Runs parenteral (blood) and non-parenteral (enteral) fluids
  • Uses standard fullfill, partfill, syringe, and vial containers

phone Call for price: (855) 477-8866

Download the operator's Manual

Description

Abbott Plum XL

So here you will be able to find the specifications of the Abbott Plum XL Infusion Pump Repair. Here are the physical, alarms, electrical and delivery rate ranges and etc.

Physical:
  • Dimensions: Approximately 8.25H x 7.5W x 8.75D inches (including pole clamp)
  • Weight: Approximately 7.75 lbs (with battery)
  • Casing: High-impact plastic
Electrical:
  • Power Requirements: 100-130 VAC, 50 to 60 Hz, less than 35 W
  • Power Cord: Hospital-grade AC cord, 10 feet long, with transparent plug
  • Fuses: 0.5 A, 250V, slow-blo
  • Battery: Sealed lead-acid rechargeable 8 V battery, internal to infusion system. Accessible for ease of field replacement, with color-coded leads and polarized connector
  • Battery Operation: A fully-charged new battery will provide eight hours of operation at 125 ml/ hr, or 1000 ml total volume delivered.
  • Recharge Time: Approximately 16 hours (operating at 125 ml/hr). If the infusion system is turned to OFF/CHARGE, recharge takes approximately 8 hours.
    • The battery charges whenever the infusion system is connected to AC (mains) power
Delivery Rate Range:
  • Primary, Secondary Mode: 1 to 999 mL/hr (in 1 mL increments)
  • KVO: 1 mL/hr
  • Dose Limit Range: 1 to 999 mL/hr (in 1 mL increments)
  • Occlusion Range (Distal): 10 psi (+5, -2 psi)
Alarms:
  • Occlusion
  • Air-in-line
  • Turn to run
  • Low battery
  • Door/Cassette
  • Set rate
  • Check settings
  • VTBI complete

Abbott Plum XL

So here you will be able to find the specifications of the Abbott Plum XL Infusion Pump Repair. Here are the physical, alarms, electrical and delivery rate ranges and etc. The battery charges whenever the infusion system is connected to AC (mains) power

Physical:
  • Dimensions: Approximately 8.25H x 7.5W x 8.75D inches (including pole clamp)
  • Weight: Approximately 7.75 lbs (with battery)
  • Casing: High-impact plastic
Electrical:
  • Power Requirements: 100-130 VAC, 50 to 60 Hz, less than 35 W
  • Power Cord: Hospital-grade AC cord, 10 feet long, with transparent plug
  • Fuses: 0.5 A, 250V, slow-blo
  • Battery: Sealed lead-acid rechargeable 8 V battery, internal to infusion system. Accessible for ease of field replacement, with color-coded leads and polarized connector
  • Battery Operation: A fully-charged new battery will provide eight hours of operation at 125 ml/ hr, or 1000 ml total volume delivered.
  • Recharge Time: Approximately 16 hours (operating at 125 ml/hr). If the infusion system is turned to OFF/CHARGE, recharge takes approximately 8 hours.
    • The battery charges whenever the infusion system is connected to AC (mains) power
Delivery Rate Range:
  • Primary, Secondary Mode: 1 to 999 mL/hr (in 1 mL increments)
  • KVO: 1 mL/hr
  • Dose Limit Range: 1 to 9999 mL/hr (in 1 mL increments)
  • Occlusion Range (Distal): 10 psi (+5, -2 psi)
Alarms:
  • Occlusion
  • Air-in-line
  • Turn to run
  • Low battery
  • Door/Cassette
  • Set rate
  • Check settings
  • VTBI complete

Related Keyphrase:

  • Abbott Plum XL Infusion Pump

Download the operator’s Manual

https://web.facebook.com/infusionpumprepair/photos/a.101426038761773/103546551883055

 

Leave a Reply

Your email address will not be published. Required fields are marked *