Sigma Spectrum
- Large and smal volume parenterals
- Neonatal
Administration Set
Compatible with standard gravity IV sets supplied by Baxter and Hospira and several other companies.
Description
The Spectrum and Spectrum with Master Drug Library is intended to be used for the controlled administration of intravenous fluids. These fluids may include pharmaceutical drugs, blood, blood products, and mixtures of required patient therapy. The intended routes of administration consist of the following clinically acceptable routes: intravenous, arterial, subcutaneous, intrathecal, epidural or irrigation of fluid space. The Spectrum is intended to be used in conjunction with legally marketed intravenous administration sets and medications provided by the user.
The Spectrum and Spectrum with Master Drug Library are suitable for many user facility applications such as, but not limited to, hospitals, outpatient care areas, home care, and ambulatory care services.
The Spectrum and Spectrum with Master Drug Library are intended to reduce operator interaction through guided programming, thereby helping to reduce errors associated with complex device programming. Parameter programming requires trained health care professional confirmation of limits and drug therapy to physician’s directive.
Dimensions: |
6.3” H x 6.4” W x 4.7” D with pole clamp and wireless battery |
Weight: | 2 lbs and 2.5 oz. |
Display: |
Color, 240 x 270, LED Front-Lit, 0.2235 mm X 0.2235 mm dot pitch |
Pumping Mechanism: | Linear peristaltic |
AC Power: |
Input 100VAC - 240VAC, 50-60 Hz/200 mA |
Battery Power & Capacity Wireless Battery Module (802.11b/g): |
Lithium Ion, 1800 mA/h, 7.4 VDC nominal (Part No: 35162) |
Alarm Volume: | 3 levels – high, medium, and low |
Alarms & Alerts: | Air-in-line, Downstream Occlusion, Very Low Battery, Due for inspection |
Logging Memory: | 10,000 ± event capacity; Separate pump history log and drug event log |
Anti-Free-Flow System: | Set based, utilizing IV set slide clamp. |
Dose Modes: | Over 20 Modes, including: mL/hr, mg/hr, mcg/hr, mg/kg/hr, mcg/min |
Flow Rate: |
0.5 to 999 mL/hr with 0.1 mL/hr increments from 0.5 to 99.9 mL/hr and 1.0 mL/hr increments from 100 to 999 mL/hr |
Infusion Modes: | Primary and Secondary, Multi-Step, and Cyclic TPN |
KVO: |
The default KVO rate is set at 1 mL/hr but may be configured to between 0.5 – 50 mL/hr. |
Maximum Pump Pressure: | 28 PSI |
Occlusion Pressure: | High (19 ±9 PSI), Medium (13 ±6 PSI), and Low (6±4 PSI) |
Operational Conditions: |
Operating temperature: 60 to 80°F (15.6 to 26.7° C), 20 to 90% relative humidity, non-condensing |
Storage Temperature: |
Storage temperature: -4 to 120°F (-20 to 49°C), 10 to 90% relative humidity, non-condensing |
Total Drug Delivered: |
0.1 to 9999 mL with 0.1 mL increments from 0.1 to 99.9 mL and 1.0 mL increments from 100 to 9999 mL |
Volumetric Accuracy (using Baxter Standard IV Sets): | ±0.1mL/hr at 0.5 – 1.9 mL/hr ±5% at 2.0 – 999 mL/hr |
Wireless Network Interface (w/Wireless Battery Module (802.11b/g): | Standard: IEEE 802.11b/g Transmit Power: 12 dBm typical |
|
- Intercompatability with the Electronic Medical Record (ERM) to help improve clinical workflow and data documentation accuracy
- A Dose Change alert can catch potential programming errors
- Average 96% drug library compliance that maximizes use of the key safety feature
- Recognized programming ease-of-use that is designed to guide users and help minimize the number of programming errors
- Large font with color display; easytoread screen with onscreen guidance
- Standard, 802.11b Wireless, and 802.11 b/g Wireless Battery Modules available
- The built-in asset tracking capabilities will help quickly locate pumps for use and manage pump inventory when used in conjunction with an asset management solution