Alaris Signature 7230

The Alaris IVAC Signature Gold 7230 Infusion Pump is a dual-channel device with independent programming on each channel. It can be used for general IV infusions, antibiotics, blood infusions, enteral infusions, TPN and hyperalimentation, and lipids. Monitoring options provide increased awareness of occlusion detection and battery charge condition. Dual-rate piggyback function and panel lock.

A multi-step program function allows a sequential program to deliver up to nine rates and volumes; can also be programmed using volume and time. Multiple infusions can be preprogrammed over a period of up to 24 hours; delay start and loading dose features. Computer interface for remote monitoring. Rotating pole clamp for pole or bed-rail mounting. Drug-specific dose rates can be calculated by selecting a drug name, which will then display on the screen. Recommended for epidural infusions. Optional flow sensor.

Description

The Alaris IVAC Signature Gold 7230 Infusion Pump is a dual­channel device with independent programming on each channel. It can be used for general IV infusions, antibiotics, blood infusions, enteral infusions, TPN and hyperalimentation, and lipids. Monitoring options provide increased awareness of occlusion detection and battery charge condition. Dual­rate piggyback function and panel lock.

A multi­step program function allows a sequential program to deliver up to nine rates and volumes; can also be programmed using volume and time. Multiple infusions can be preprogrammed over a period of up to 24 hours; delay start and loading dose features. Computer interface for remote monitoring. Rotating pole clamp for pole or bed­rail mounting. Drug­specific dose rates can be calculated by selecting a drug name, which will then display on the screen. Recommended for epidural infusions. Optional flow sensor.

Specifications
Dimensions:  10.7” W x 8.6” H x 5.0” D (without power cord) 
Weight:  8.4 lbs/3.8 kg (without pole clamp) 
Power Cord:  10 ft 
Case:  Impact and flame resistant plastic
Power Requirements:

100­120 V~,50/60 Hz, 0.5 A, 3­wire grounded system (40 watts Max)

Battery:

Rechargeable nickel cadmium. With a new, fully charged battery, the pump will operate for 4 hours nominal.

Operating Conditions: 50­ - 104° F and 20­90% humidity, non­condensing
Storage Conditions: -40 - 140° F and 5­95% humidity, non­condensing
Ground Current Leakage:

Tested to UL 544 and CSA C22.2 No. 125 for medical and dental equipment.

Mode of Operation: Continuous
KVO Flow Range: 0.1 - 20.0 ml/hr in 0.1 ml/hr increments

Flow Rate Range: 

- 0.1 to 999.9 ml/hr in 0.1 ml/hr increments (primary) 
- 0.1 to 270.0 ml/hr in 0.1 ml/hr increments (secondary)
Flow Rate Accuracy: ±5% at 1.0 ­ 999.9 ml/hr; ±6.5% at 0 ­ 1.0 ml/hr
Volume To Be Infused Range:

- 0.1 to 9999.9 ml in 0.1 ml increments (primary and dose rate modes) 
- 0.1 to 999.9 ml in 0.1 ml increments (secondary)

Volume Infused Range: - 0.0 to 9999.9 ml in 0.1 ml increments
Alarms:

Alarms ­ Accumulated Air in Line

  Air in Line
  Battery Depleted
  Channel Malfunction
  Computer Link Failure
  Flow Sensor Unplugged
  Hold Time Exceeded
  Instrument Malfunction
  Key stuck
  Latch Open
  No Upstream Flow Detected
  Occlusion Downstream
  Occlusion Upstream
  Primary Flow Detected during Secondary
  Set Out ­ Set Up Time Exceeded